Normal activity (led on even without
photo-
cells). No registered photocell
engaged
.
At
least one registered photocell
engaged
or not
aligned
.
Off
(flash
every
2.5 secs)
BUS-2EASY
line
short
-circuited
.
BUS-2EASY
line
deactivated
.
OPENING
and
CLOSING
Max.
2
pairs
4.1
BUS-2EASY
PHOTOCELLS
This
board
is
equipped
with a
BUS-2EASY
circuit that
can
be used to
easily
connect a high number of
auxiliary
BUS
-
2EASY
devices to the safety device (e.g. up to 16
pairs
of
photocells), appropriately
programmed,
using only two
cables without polarity.
Before
connecting
the photocells, it
is
advisable to select
the type of operation
(Fig.
3) on the basis of the area
of
movement the cells must protect and to position the
dip
switches on both the transmitter and receiver (see
Fig.
4)
as in
T
ab
. 1.
4.1.1
ADDRESSING BUS-2EASY
PHOTOCELLS
It
is
important to give both the transmitter
and the receiver the same address.
F
ollow the
instructions
in the following table to check
that
the
BUS-2EASY
connection
status is
efficient
.
T
ab.
2 -
Description
of
BUS-2EASY
led
Ensure
that there are not two or more pho-
tocell pairs with the same address.
If
no
BUS-2EASY
accessory
is
used,
leave the
BUS-2EASY
connector (J12 - fig. 1)
free.
T
ab.
1 -
Addressing
BUS-2EASY
photocells
4.2
TRADITIONAL
PHOTOCELLS
Connection of 1 pair of closing
photocells
with
FAIL-SAFE
safety device
activated
Set
in second level of programming
o 1
=
0 1
OUT
/
S
A
F
E
/
S
A
F
E
Other safety
devices
OUT
OUT
Connection of 1 pair of closing
photocells
with
FAIL-SAFE
and
STOP
safety device
deactivated
Other safety
devices
/
S
A
F
E
/
S
A
F
E
4.1.2
STORING BUS-2EASY
ACCESSORIES
It
is
possible to add
BUS-2EASY
photocells to the
system
at
any time, simply by following the procedure
below:
1. Install and
programme
the accessories with the re-
quired address (see par. 4.1.1).
2. Cut off power to the
board
.
3. Connect both cables of the
BUS-2EASY
accessories
to
the red terminal block J12 (polarity irrelevant).
4.
P
ower the
board
.
5. Quickly press the
SETUP
push-button
(SW4)
once
to
register the accessories. Check the operation of
the
installed
BUS-2EASY
devices
.
6.
The
board has stored the
BUS-2EASY accessories
.
Fig.
5
If the
FAIL-SAFE
safety device
is
not
used,
connect the power
supply
of the transmit-
ters to terminals 6 and 8 of J13.
If the
FAIL-SAFE
safety device
is uses,
con-
nect the power supply of the transmitters
to
OUT
after setting it as appropriate (see
2nd level programming and
Fig.
16).
If the
FAIL-SAFE
safety
device
is used,
even the
unused
safety inputs must
be
connected
via
a
shunt
lead to the
negative of
OUT (see Fig.
16).