FAAC C720 - Storing Ds Radiocontrols; Storing Radio Code

FAAC C720
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
ENGLISH
Display
F
unction
Default
1
AS
SERVICE REQUEST
-
CYCLE COUNTER
(combined
with
the two
successive
functions):
Y
=
when the set number of cycles
is
reached with successive functions
nc
and
nd
,
the
system carries
out an 8 sec. preflashing sequence
(in
addition to the sequence
already
set using the
PF
function) before each
movement
.
no
=
successive
functions
nc
and
nd
indicate how many cycles the
system has
per
formed
up to the maximum possible display of 99.990.
If the number of cycles
is
higher than 99.990, the two
successive
functions
nc
and
nd
will show
99 and 99 respectively.
This
function may be
useful
for setting
programmed maintenance
operations or for
checking
work
cycles per
formed
.
no
nc
CYCLE PROGRAMMING
(THOUS
ANDS):
If
AS
=
Y
the display indicates the number of thousands of cycles after which service
is
required (may be set from 0 to
99
).
If
AS
=
no
the display indicates the number of thousands of cycles performed.
The
value
displayed
is
updated
with the sequence of cycles, interacting with the value of
nd
.
If
AS
=
no
press keys
+
and - for 5 sec. to zero the cycle counter
.
00
nd
CYCLE PROGRAMMING (TENS):
If
AS
=
Y
the display indicates the number of tens of cycles after which service
is
required
(may be set from 0 to
99
).
If
AS
=
no
the display indicates the number of
tens
of cycles performed.
The
value displayed
is
updated
with the sequence of cycles, interacting with the value of
nc
.
Example: if the
system
has performed 11.218, it will display
nc
=
11
and
nd
= 21
00
St
STATUS
OF
AUTOMATED SYSTEM:
Exit
from
programming,
data storage, and return to gate status
display.
00
=
CLOSED
07
=
FAIL SAFE
in progress
01
=
OPEN
08
=
BUS-2EASY
device check in progress
02
=
Stop then OPEN
09
=
P
reflashing
then OPEN
03
=
Stop then
C
L
OSE
10
=
P
reflashing
then
C
L
OSE”
04
=
In
P
AUSE”
11
=
OPEN
in
P
artial
Opening
05
=
During opening stage
12
=
in
PAUSE
P
artial
Opening
06
=
During closing
stage
6
STORING RADIO
CODE
The electronic
device
is
equipped
with an in-
tegrated dual
channel
decoding
system
(DS
,
SLH
, LC/RC) known as
Fig.
12
6.1
STORING DS
R
ADIOCONTROLS
It
is
possible to store a maximum of
256
codes divided between
OPEN
A and OPEN
B/CLOSE.
1. On the
DS
radiocontrol, select the required ON - OFF
OMNIDEC.
This
system
O
can use an
additional
receiving module
(Fig.
5
re.
G))
and radiocontrols
combination
of the 12 dip-switches.
2.
Press
and hold down push-button
+
(SW3)
or
-
(SW2)
and then
press
the
SETUP
push-button
(SW4),
to store
total opening
(OPEN
A) or partial opening
(OPEN
B/
of the same frequency to
store
both total opening
(OPEN
A)
and partial opening
(OPEN B)
of the
automated
system.
The
3
types
of radio coding
(DS, SLH,
LC/RC)
3.
can co-exist at the same time on the two
4.
channels. It
is possible
to enter up to
256
radio codes subdivided between
OPEN
A
5.
and
OPEN
B.
To
use the different coding
systems
on the
same channel,
finish
the learning process
6.
for each
system
and then repeat the pro-
cedure for another
.
CLOSE)
respectively.
The
corresponding led
will
begin
to flash
slowly
for 5 secs.
R
elease both push-buttons.
Within
this 5 second period,
press
the required push-
button on the radiocontrol.
The
corresponding led will come on with a fixed light
for 1 second and then go off to indicate the setting
has been stored.
T
o
add other codes other than the one you have re-
cently stored, repeat the procedure from point 1.

Other manuals for FAAC C720