PARTIAL
OPENING:
It
is
possible to adjust the width of the partial leaf opening as a percentage of the total
gate
travel.
Adjustable from 0 to 99% in 1% steps.
00
=
no partial
opening
01
=
minimum partial
opening
99
=
maximum partial
opening
TIME-OUT
It
is
advisable to set a value higher than the time taken by the gate to open or close fully.
Adjustable from 0 to
59
sec. in 1 second steps.
Subsequently,
display changes to minutes
and tens of seconds (separated by a point) and time
is
adjusted in 10-second steps, up
to
the maximum value of
9.5
minutes
.
E
.
g
.: if the display
shows
2.5
, pause time
is
2 min. and 50 secs.
OUT
1:
Allows
output
OUT
(open collector N.O.) to be activated in one of the following functions:
00
=
Always
active
01
=
F
AIL
-
SAFE
02
=
WARNING LIGHT
(off when closed, on during opening
and
open/pause, flashing during
closing)
03
=
COURTESY LIGHT
(see next function)
04
=
ALARM,
BATTERY
operation
05
=
gate
OPEN
or
P
AUSED
06
=
gate CLOSED
07
=
gate in MOTION
08
=
gate OPENING
09
=
gate CLOSING
1 0
=
ACTIVE
safety
1 1
=
timed output that can be activated by second radio channel (see next function)
1 2
=
output that can be activated by second radio channel (step function)
TIMING
OF
OUT
1
(only
if option
03
or
11
is
selected at the
previous
step):
Can be used t o adjust timing of output
OUT
if a timed function was
selected
(e.g. 03 or
1 1
)
from
1
to
99
minutes in 1 minute steps.
OPEN B
/
CLOSE
/
EDGE SAFETY
DEVICE:
It
is
possible to select the use of
OPEN B
input as partial opening,
CLOSE
command
or EDGE
SAFETY
DEVICE.
00
=
OPEN B
01
=
CL
OSE
02
=
EDGE SAFETY
DEVICE
If
you select
a
function logic
that
involves
the
use
of the
CLOSE
command
(logic
b
,
bC
,
C
)
this function will
be
preset
to
01
and it
will not
be
possible
to change it.
STOP
/
EDGE SAFETY
DEVICE
It
is
possible to select the use of
STOP
input as
STOP
or
EDGE SAFETY
DEVICE.
00
=
ST
OP
01
=
EDGE SAFETY
DEVICE
MOTOR
L
OCK:
It
is
possible to select the use of the motor lock during battery
operation:
Y
=
the motor lock
continues
to operate
regularly
even
during
battery operation
no
=
when the system switches to battery operation, the motor lock remains
open
.