EasyManua.ls Logo

FAAC C720 - Mechanical Installation

FAAC C720
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.3 MECHANICAL INSTALLATION
1. Remove the cover casing by loosening the two suitable side bolts and lifting it (Fig. 8).
2. Position the operator on the foundation plate using the nuts and washers provided as shown in Fig. 9. During this operation,
pass the cables though openings in the motor casing (see Fig. 9 re. 1).
Fig. 8 and Fig. 9 refer to operator C720 /E-SL1800
3. Adjust the height of the gearmotor and the distance from the gate with reference to the dimensions in Fig. 10.
Operation required for correct fastening of the rack and to keep open the option of new adjustments.
4. Secure the gearmotor to the plate by tightening the fastening nuts.
5. Prepare the gearmotor for manual operating mode as described in
paragraph 8.