MOTOR
POWER:
Adjusts
the motor power level
01
=
minimum power
50
=
maximum power
When the power value has been changed, it
is
advisable to perform a new
SETUP
(see par. 7.3)
OPENING SPEED:
Adjusts
the motor opening speed to 10 levels
0 1
=
minimum
speed
1 0
=
maximum
speed
When the speed value has been changed, it
is
advisable to perform a new
SETUP
(see par. 7.3)
CLOSING SPEED:
Adjusts
the motor closing speed to 10 levels.
0 1
=
minimum
speed
1 0
=
maximum
speed
When the speed value has been changed, it
is
advisable to perform a new
SETUP
(see par. 7.3)
SL
OWING
DURING
OPENING
Adjusts
the slowing space as a
percentage
of the total gate travel. Adjustable from 5 (with
speed <5),
10
(with
speed between 5 and 8),
15
(with
speed >8) to
99
% in 1% steps.
5- 10- 15
=
minimum slowing
99
=
maximum slowing
SL
OWING
DURING
CLOSING:
Adjusts
the slowing space as a
percentage
of the total gate travel. Adjustable from 5 (with
speed <5),
10
(with
speed between 5 and 8),
15
(with
speed >8) to
99
% in 1% steps.
5- 10- 15
=
minimum slowing
99
=
maximum slowing
SPEED
DURING
SL
OWING:
Adjusts
gate speed during
slowing
.
0
=
LOW
speed
1
=
HIGH
speed
STATUS
OF
AUTOMATED SYSTEM:
Exit
from
programming,
data storage, and return to gate
status display
.
00
=
CLOSED
07
=
FAIL SAFE
in progress
01
=
OPEN
08
=
BUS-2EASY
device check in progress
02
=
Stop then “OPEN”
09
=
P
reflashing
then “OPEN”
03
=
Stop then “
C
L
OSE”
10
=
P
reflashing
then “
C
L
OSE”
04
=
In “
P
AUSE”
11
=
OPEN
in
P
artial
Opening
05
=
During opening stage
12
=
in
PAUSE
P
artial
Opening
06
=
During closing
stage