BEISSBARTH MT 740/ 745, 741/ 746
6-2
The microprocessor automatically calculates the precise distance
between the rim flange and the actual point at which the weights
should be attached.
The choice of weight positions is likewise displayed on the screen
by means of symbols.
Grams/ounces selector key (10).
Press this key for 2 seconds to change between weight displays in
grams and ounces.
Delete key (18). When this key is pressed, the entered data are
deleted and the basic symbol appears on the screen.
Inhibit key (17). If this key is held depressed for about 5 seconds, the
gram inhibit function is deactivated and the machine is set ready for
precision wheel-balancing.
To set the gram inhibit threshold to 5 g shutdown, press this key briefly;
press the key again to set the threshold to 10 g deactivation.
At the same time, at any gram inhibit selected, the rounding-off
program with display stages rounded up or down to 5 grams or 0.25
ounces is activated.
The bar symbols on the monitor indicate the selected inhibit stages.
green redyellow
Precision
balancing
without inhibit
10g inhibit
+ rounding off
5g inhibit
+ rounding-off