EasyManua.ls Logo

Fagor BCSD-10D - I;O Signal Names and Functions

Fagor BCSD-10D
118 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BCSD-40/116 Digital Brushless AC Servo Drive system - Ref. 1809
3.2.2. I/O Signal Names and Functions
Input Signals.
Output Signals.
Control
Mode
Signal
Name
Pin
No.
Function
Speed
/S-ON 14 Servo ON: Turns the servomotor on.
P-OT
N-OT
16
17
Forward run prohibited
Reverse run prohibited
Overtravel prohibited:
Stops servomotor when OFF.
/ALM-RST 39 Alarm reset: Releases the servo alarm state.
DICOM 13
Control power supply input for I/O signals: Provide the +24 V DC power
supply.
VREF+ 1
Speed reference input: ±10 V.
VREF- 2
Control
Mode
Signal
Name
Pin No. Function
Speed
ALM+ 7
Servo alarm:
Turns off when an error is detected.
ALM- 8
/S-RDY+ 9 Servo ready:
ON if there is no servo alarm when the control/main circuit power
supply is turned ON.
/S-RDY- 10
PAO+ 20
Phase-A signal
Converted two-phase pulse (phases A and B)
encoder output.
PAO- 21
PBO+ 22
Phase-B signal
PBO- 23
PCO+ 24
Phase-C signal Zero-point pulse (Phase-C) signal.
PCO- 25
FG Shell
Connected to frame ground if the shield wire of the
I/O signal cable is connected to the connector shell.
Reserved -
4, 18, 19, 29,
35, 36, 37, 38,
43, 44, 45, 47,
49.
Not used.

Table of Contents