3. Installation instructions
>
12
VERY IMPORTANT: Before fitting the left side panel, tightly secure the power cable
in the cable gland.
When several appliances are installed in line, they must be connected to each other
by means of a grounding point located at the base of the equipment at the rear. The
connection is indicated by the following symbol.
3.6.1 Electrical characteristics of ELECTRIC OVEN models
Model
Hose section
Nominal
current
General
internal
fuse
Differential
switch
Total
power
kW
C_A-0623-E
C_AW-0623-E
C_AP-0623-E
C_APW-0623-E
3x1.5mm
2
+N+T
8.9A
10A
300mA
6.2
3x2.5mm²+T
15.6A
20A
300mA
3x2.5mm²+T
17.9A
20A
300mA
2x4mm²+T
27A
32A
300mA
C_A-061-E
C_AW-061-E
C_AP-061-E
C_APW-061-E
3x2.5mm
2
+N+T
16.9A
20A
300mA
11.7
3x6mm²+T
29.4A
32A
300mA
3x6mm²+T
33.8A
40A
300mA
2x10mm²+T
50.9A
50A
300mA
C_A-062-E
C_AW-062-E
C_AP-0623-E
C_APW-0623-E
3x6mm
2
+N+T
32.9A
40A
300mA
22.8
3x16mm²+T
57.2A
63A
300mA
3x16mm²+T
65.8A
80A
300mA
C_A-101-E
C_AW-101-E
C_AP-101-E
C_APW-101-E
3x6mm
2
+N+T
27.7A
32A
300mA
19.2
3x10mm²+ T
48.2A
50A
300mA
3x16mm²+ T
55.4A
63A
300mA
C_A-201-E
C_AW-201-E
C_AP-201-E
C_APW-201-E
3x16 mm
2
+N+T
55.4A
63A
300mA
38.4
3x35mm²+ T
96.4A
100A
300mA
3x35mm²+ T
110.9A
125A
300mA
C_A-102-E
C_A-102-E
C_AP-102-E
C_APW-102-E
3x10mm
2
+N+T
49.4A
63A
300mA
34.2
3x25mm²+ T
85.8A
100A
300mA
3x35mm²+ T
98.7A
125A
300mA
C_A-202-E
C_AW-202-E
C_AP-202-E
C_APW-202-E
3x35mm
2
+N+T
98.7A
125A
300mA
68.4
3x70mm²+ T
171.7A
180A
300mA
3x95mm²+ T
197.5A
225A
300mA
Equipotential bonding
symbol

Table of Contents