3. Installation instructions
>
15
If the pipe pressure differs from the fluid pressure, inform the gas supply
company. The appliance must not be operated above 30 mbar with natural gas.
Shut off the gas supply to the appliance.
Operating pressures above 60 mbar are not permitted, as some components of
the equipment may become inoperative.
3.8 Ventilation of the room
This equipment must be installed in such a way that the ventilation conditions are sufficient to
avoid the accumulation of unauthorised concentrations of fumes and products released during
combustion, which are harmful to health.
It is advisable to install an exhaust hoodfood for the extraction of fumes and vapours in
compliance with the standard UNE100165:2004. The hood should protrude 200-400mm from
the front of the equipment.
We recommend that gas-related components are serviced annually by an authorised
technician.
Category, gases and operating pressures
Country
Category
Pressure
AT
II
2H3B/P
20*50
AL - BG - DK - EE - FI - HR - LT - LV - MK - NO - RO - SE
II
2H3B/P
20*30
BE - FR
II
2E+3+
20/25*28-30/37
CH - CY - CZ - ES - GB - GR - IE - IT - PT - SI - SK - TR
II
2H3+
20*28-30/37
DE - LU
II
2E3B/P
20*50
PL
II
2E3P
20*37
HU - IS - MT - NL
I
3B/P
30
In order to extract the combustion products, gas appliances can be installed in different ways
depending on the requirements of the installation.
Incorrect connection may result in a fire hazard.