DC Servo Drive System Manual Ver: 0009
DC - 6/32
1.3 TORQUE-SPEED CURVES
1. Work area in continuous
duty cycle S1. Torque
available in continuous
mode.
2. Work area in intermittent
duty cycle. Torque available
in cyclic acceleration and
deceleration.
3. Work area in sporadic
acceleration and
deceleration. Working in this
area, reduces the life span
of the brushes.
L.S. Demagnetizing limit at 25°C (77°F). The DCS drive, equipped with the proper IM board, watches
the motor so it never exceeds those demagnetizing currents.
1
0.5
10
50
04000rpm
DCM21 DCM22 DCM23
Nm
5
30001000
DCM41
DCM52
1
0.5
10
50
04000rpm
Nm
5
30001000
1
0.5
10
50
03000rpm
Nm
5
25001000
DCM43
1
10
100
0rpm
Nm
5
1000 2000 3000
3
2
20
50
1200
DCM42
1
10
100
0rpm
Nm
5
1000 2000 3000
3
2
20
50
1200
1
10
100
0rpm
Nm
5
1000 2000 3000
3
2
20
50
1200
DCM52
1
10
300
Nm
50
100
0 rpm 1000 2000 30001200
1
10
300
Nm
50
100
0 rpm 1000 2000 30001200
3
2
3
1
2
1
2
1
2
1
2
1
3
2
1
3
2
1
1
2
3
LS