EasyManua.ls Logo

Falcon Professional + - Technical Data

Falcon Professional +
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
Technical Data
This cooker is category II2H3+
It is supplied set for group H natural gas. A conversion kit from NG to LP gas is packed with the cooker.
 Please leave these instructions with the User.
 Cooker back, serial number repeater badge below oven door opening.
 GB
(Rp ½ at rear right-hand side) 
 20mbar 220 - 240V 50Hz
 29mbar
 37mbar
(See appliance data badge for test pressures)


minimum 903mm maximum 930mm

1100mm; see ‘Positioning of Cooker

648mm

See ‘Positioning of Cooker’

650mm

 

 
Right-hand Wok burner 3.5kW
internal 80
3.5kW (255g/h)
internal 54
external 129 external 77
Large Burners 3.0kW 134 3.0kW (218g/h) 87
Medium Burners 1.7kW 109 1.7kW (124g/h) 68
Small Burner 1.0kW 75 1.0kW (73g/h) 51
Gas burner inputs based on Gross Calorific Value

 
Oven Browning Element
2.2 kW 1.15kW 2.5 kW
Energy efficiency class:
on a scale of A (more efficient) to G (less efficient)
A A
Energy consumption based on standard load 0.99kWh 0.85kWh
 67 67
 Large Large
 40 minutes 38 minutes
 1400cm² 1400cm²

2.3kW
Maximum total electrical load at 230V 7.1kW (approximate total including oven lights, oven fan, etc.)

Related product manuals