A link code of 000 (default) means that this SYSEX message is not linked, and will not trigger any further messages after
it sends its message. Otherwise, select a valid Sysex message to link to. If you link a Sysex message to itself, it will loop
for 16 iterations before it exists. This is NOT recommended under any circumstances.
For each Sysex message, we need to program from 1 to 16 bytes of data. Each byte can have a value from 0 to 7F (hex)
or 0-127 (DEC). This is done by programming one byte at a time. Using the and buttons
will select the byte to program. Pressing the or buttons will increase or
decrease the data value stored. The display will show the value in both HEX and DEC format. Leave all unused bytes at a
value of 0.
DO NOT FORGET TO PRESS after each modified byte before moving to the next.
BYTE # being Edited VALUE TO STORE