-83-
Alarm reset
Always reset an alarm after ensuring safety by removing the cause of the alarm and turning the
operation signal OFF.
Alarm release
Always release an alarm after ensuring safety by removing the cause of the alarm and turning the
operation signal OFF.
Alarm release method
- After the operation swich is set to STAND-BY, it can be released by pressing the S button.
- Turn off the power, wait for at least 1 minute, and then cycle the power.
Attention
If the product dose not operate properly after the power is cycled, the
internal circuit may be damaged. Contact your nearest sale office.
Continuing the operation without removing the cause of the alarm may cause
malfunction of the equipment.
Reset using the ALARM-RESET input
Turn the operation signal OFF and then turn ALARM-RESET input ON (Keep it ON for 10 msec or
more). The ALARM-RESET input is disabled while the operation signal is being ON. The figure
showns an example for which the operation signal is the FWD input.
Alarm records
Up to 10 generate alarms to save in NVM (Non-volatile memory) in order of the latest to oldest.
When clearing the alarm records, perfrom the alarm record clear on the monitor mode.