LCD DISPLAY ERROR MESSAGES
(# stands for the barrel number which is L, C, R, or 1, 2, 3, 4)
FBD56X SERIES FROZEN BEVERAGE DISPENSERS
MESSAGE DESCRIPTION WILL CAUSE
DefPMx Chamber pressure is above 55 psig during defrost only.
DefPrO Product is out during defrost only.
BTR-LO Low beater percent. Below 450%. Fault Code History.
BTR-HI High beater percent. Above 1200%.
SYROUT Syrup pressure is below 35 psig. Fault Code History.
H2OOUT Water pressure is below 35 psig. Fault Code History.
CO2OUT CO
2 pressure is below 45 psig. Fault Code History.
PresMx Chamber pressure is above 55 psig during normal Fault Code History.
operations only.
RunPrO Product out during normal operations.
RTempE High return temperature detected or temperature sensor
broken (-40 to 97). Unit still functions.
MaxFil Regulated CO2 pressure is at or above 40 psig limit.
Tnk Psi=0 # Filling has been on for 30 seconds and chamber pressure Fault Code History.
equals to zero (0).
SFil Error # Filling on for four (4) minutes but chamber pressure Fault Code History.
between one (1) psig and fill psig.
ProdOt Product out when side needs to be filled.
InTempE High inlet temperature detected or temperature sensor
broken (-40 to 97). Unit still functions. This error will occur
during the DEFROST CYCLE.
Cmp ran too The compressor has run for more than one hour straight in
long OFF a 562 or 563 dispenser (one hour and 20 minutes for the 564 All barrels go to OFF.
dispenser). Check the air filter or the refrigeration charge.
HOT PRODUCT This means the product in the barrel is getting hot. A bad All barrels go to OFF.
SHUT DOWN return temperature sensor may also be at fault.
Stop BTR Long The beater shuts off after fifteen (15) minutes of a PMAX error. This barrel goes to OFF.
PMAX It will restart automatically when the error is cleared.
Stop BTR The beater shuts off after fifteen (15) minutes of a sold-out
LongPrd Out condition. It will restart automatically when the sold-out This barrel goes to OFF.
has been cleared.