System diagnostics
The values of the sensors and actuators in the boiler are available.
Note: To return to the Service Menu, touch the arrow at the top left of the screen
Transparent Parameters “B” menu
A
By selecting a parameter on the screen, the possible values will be shown. If the values shown do not match
those indicated in the corresponding "Range" column, check that the parameter B01 is correctly set to RRT.
Description Range
Combustion
Burner power 00%=Min., 100%=Max.
Flame status 00÷255
Fan rpm 00÷120
Operating hours 00÷99
Fume Temperature 0÷125 °C
Hydraulics
Heating Flow 0÷125 °C
Heating Return 0÷125 °C
NTC DHW sensor (°C) 0÷125 °C
DHW draw-off 00÷99 L/min
Modulating pump speed 00÷100%
System water pressure 00-9.9 bar with pressure transducer
Environment
External probe +70 ÷ -30°C
Code Description Range Default
B01 Boiler type selection
RRP (INSTANTANEOUS COMBI)
RRH (HEATING ONLY also with OPTIONAL HOT WATER STO-
RAGE TANK
RRT (COMBI HEATING ONLY)
RRK (HEATING ONLY with HOT WATER STORAGE TANK)
RRT
B02 Exchanger type 1 ÷ 4
BLUEHELIX MAXIMA 24C = 1
BLUEHELIX MAXIMA 28C = 2
BLUEHELIX MAXIMA 34C = 3
B03
Absolute Maximum Heating
Power
0 ÷ 100% (Do not modify the value)
BLUEHELIX MAXIMA 24C = 75%
BLUEHELIX MAXIMA 28C = 85%
BLUEHELIX MAXIMA 34C = 85%
B04
System water pressure pro-
tection selection
Pressure switch
Pressure Transducer
Pressure transducer
B05 NOT IMPLEMENTED --
B06
Variable input contact ope-
ration selection
Flow meter exclusion
System thermostat
Second room therm.
Warning/Alert
Safety thermostat
Second room thermostat
B07 Relay card LC32 selection
External gas valve
Alarm
System filling solenoid valve
Solar 3-way valve
Second heating pump
Alarm2
Burner lit
Frost protection active
System filling solenoid valve