22
confIguratIon
34. Alarm conguration - 5th slot
This parameter determines to which alarm frames and how the
device should react. The parameters consist of 4 bytes, three most
signicant bytes are set according to the ocial Z-Wave protocol
specication.
X – channels summarized: 1/2/3/4 channel are equal to values
1/2/4/8. Y – sequence number: 1-10 (parameter 157).
Parameter size 4B
Default value 0 (default)
Available
values
1B [MSB] – Notication Type
2B – Notication Value
3B – Event/State Parameters
4B [LSB] – action:
0x00 – No reaction
0x0X – Turn o selected channel
0x1X – Turn on the load
0x2X – Turn o the load
0x3Y – Load blinking
35. Duration of alarm signalization
This parameter determines duration of alarm signalization.
Parameter size 2B
Default value 600 (10min)
Available
values
0 – innite signalization
1-32400 (1s-9h, 1s step)
40. Input 1 - sent scenes
This parameter denes which actions result in sending scene ID
and attribute assigned to them. Parameter is relevant only if pa-
rameter 20 is set to 2, 3 or 4.
Parameter size 1B
Default value 0 (no scenes sent)
Available
values
1 – Key pressed 1 time
2 – Key pressed 2 times
4 - Key pressed 3 times
8 – Key hold down and key released