27
confIguratIon
154. ON frame value for single click
This parameter denes value sent to devices in association groups
(using Basic Command Class).
The parameters consist of 4 bytes, each bite reserved for separate
channel, from most signicant to least signicant.
Parameter size 4B
Default value 4294967295 (0xFF FF FF FF – 255 for all channels)
Available
values
For every byte:
0-255
155. OFF frame value for single click
This parameter denes value sent to devices in association groups
(using Basic Command Class).
The parameters consist of 4 bytes, each bite reserved for separate
channel, from most signicant to least signicant.
Parameter size 4B
Default value 0 (0x00 00 00 00 – 0 for all channels)
Available
values
For every byte:
0-255
156. ON frame value for double click
This parameter denes value sent to devices in association groups
(using Basic Command Class).
The parameters consist of 4 bytes, each bite reserved for separate
channel, from most signicant to least signicant.
Parameter size 4B
Default value 0 (0x63 63 63 63 – 99 for all channels)
Available
values
For every byte:
0-255
157. Start programmed sequence
Setting this parameter will start programmed sequence with se-
lected number.
Parameter size 1B
Default value 0 (sequence inactive)
Available
values
0 – sequence inactive
1-10 – sequence number