confIguratIon
151. Local control - time between extreme values
This parameter determines time needed to change the state be-
tween extreme values (0-100%) when controlling with connected
buttons.
Parameter size 2B
Default value 3 (3s)
Available
values
0 – instantly
1-127 (1s-127s, 1s step)
128-254 (1min-127min, 1min step)
152. Remote control - time between extreme values
This parameter determines time needed to change the state
between extreme values (0-100%) when controlling via Z-Wave
network.
Parameter size 2B
Default value 3 (3s)
Available
values
0 – instantly
1-127 (1s-127s, 1s step)
128-254 (1min-127min, 1min step)
153. Active associations
This parameter allows to select which actions will result in sending
frames to associated devices.
The parameters consist of 4 bytes, each bite reserved for separate
channel, from most signicant to least signicant.
Parameter size 4B
Default value
522133279 (0x1F 1F 1F 1F – all as-
sociations active)
Available
values
For every byte:
1 – 1xclick send ON frame
(value set in parameter 154)
2 – 1xclick send OFF frame
(value set in parameter 155)
4 – 2xclick (value set in parameter 156)
8 – Hold/release sends UP frame
16 – Hold/release sends DOWN frame