confIguratIon
65. Energy reports - on change
This parameter determines the minimum change in consumed
energy that will result in sending new energy report to the main
controller.
Parameter size 2B
Default value 10 (0.1 kWh)
Available
values
0 - reports are disabled
1-500 (0.01 - 5 kWh) - change in energy
66. Energy reports - periodic
This parameter determines in what time intervals the periodic
energy reports are sent to the main controller. Periodic reports do
not depend of energy change (parameter 65)
Parameter size 2B
Default value 3600 (1h)
Available
values
0 - periodic reports are disabled
1-32400 (1-32400s) - report interval
150. Inputs - LED colour control mode
This parameter denes the inertia time of IN1 input in alarm
modes. Adjust this parameter to prevent bouncing or signal dis-
ruptions. Parameter is relevant only if parameter 20 is set to 0 or 1
(alarm mode).
Parameter size 1B
Default value 0 (RGBW mode)
Available
values
0 – RGBW mode
(every input controls output with
the same number, IN1-OUT1,
IN2-OUT2, IN3-OUT3, IN4-OUT4)
1 – HSV and White
(inputs works in HSV color model,
IN1-H(Hue), IN2-S(Saturation),
IN3-V(Value), IN4-White(OUT4)