EasyManua.ls Logo

FIBARO ROLLER SHUTTER 3 - Multichannel Command Class; Notification Command Class

FIBARO ROLLER SHUTTER 3
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
ZWAVE SPECIFICATION
Notication Command Class:
The device uses Notication Command Class to report dierent events
to the controller (“Lifeline group).
Notication
Type
Event Event Parameters
Power
Management
[0x08]
Over-current detected
[0x06]
System
[0x09]
System Hardware Failure
[0x03]
Device overheat
[0x01]
Command Class Version Secure
Endpoint 1
ZWAVEPLUS_INFO [0x5E] V2
SWITCH_MULTILEVEL [0x26] V4 YES
ASSOCIATION [0x85] V2 YES
MULTI_CHANNEL_ASSOCIATION [0x8E] V3 YES
ASSOCIATION_GRP_INFO [0x59] V2 YES
SECURITY [0x98] V1
SECURITY_2 [0x9F] V1
SUPERVISION [0x6C] V1
METER [0x32]
V3 YES
NOTIFICATION [0x71] V8 YES
APPLICATION_STATUS [0x22] V1
Endpoint 2
ZWAVEPLUS_INFO [0x5E] V2
SWITCH_MULTILEVEL [0x26] V4 YES
ASSOCIATION [0x85] V2 YES
MULTI_CHANNEL_ASSOCIATION [0x8E] V3 YES
ASSOCIATION_GRP_INFO [0x59] V2 YES
SECURITY [0x98] V1
SECURITY_2 [0x9F] V1
SUPERVISION [0x6C] V1
APPLICATION_STATUS [0x22] V1
Multichannel Command Class:

Other manuals for FIBARO ROLLER SHUTTER 3