25
ADVANCED PARAMETERS
30. Alarm conguration - 1st slot
This parameter determines to which alarm frames and how the device
should react. The parameters consist of 4 bytes, three most signicant
bytes are set according to the ocial Z-Wave protocol specication.
Available settings: 1B [MSB] - Notication Type
2B - Notication Status
3B - Event/State Parameters
4B [LSB] - action:
0 - no action
1 - open blinds
2 - close blinds
Default setting: [0x00, 0x00, 0x00, 0x00]
(disabled)
Parameter size: 4 [bytes]
31. Alarm conguration - 2nd slot (Water)
This parameter determines to which alarm frames and how the device
should react. The parameters consist of 4 bytes, three most signicant
bytes are set according to the ocial Z-Wave protocol specication.
Available settings: 1B [MSB] - Notication Type
2B - Notication Status
3B - Event/State Parameters
4B [LSB] - action:
0 - no action
1 - open blinds
2 - close blinds
Default setting: [0x05, 0xFF, 0x00, 0x00]
(Water Alarm, any notication, no action)
Parameter size: 4 [bytes]
ALARM CONFIGURATION
NOTE
Alarm with lower
number has the high-
er priority, thus rst
alarm will override
other alarms with the
same type.
i
NOTE
Setting Notication
Value to 0xFF will re-
sult in launching the
action twice: when
alarm occurs and is
cancelled.
i