26
ADVANCED PARAMETERS
32. Alarm conguration - 3rd slot (Smoke)
This parameter determines to which alarm frames and how the device
should react. The parameters consist of 4 bytes, three most signicant
bytes are set according to the ocial Z-Wave protocol specication.
Available settings: 1B [MSB] - Notication Type
2B - Notication Status
3B - Event/State Parameters
4B [LSB] - action:
0 - no action
1 - open blinds
2 - close blinds
Default setting: [0x01, 0xFF, 0x00, 0x00]
(Smoke Alarm, any notication, no action)
Parameter size: 4 [bytes]
33. Alarm conguration - 4th slot (CO)
This parameter determines to which alarm frames and how the device
should react. The parameters consist of 4 bytes, three most signicant
bytes are set according to the ocial Z-Wave protocol specication.
Available settings: 1B [MSB] - Notication Type
2B - Notication Status
3B - Event/State Parameters
4B [LSB] - action:
0 - no action
1 - open blinds
2 - close blinds
Default setting: [0x02, 0xFF, 0x00, 0x00]
(CO Alarm, any notication, no action)
Parameter size: 4 [bytes]