Questions and Answers

  • R
    Richard DennisSep 14, 2025
    What to do if the shunt field current is too low on a Fincor Controller?
    • M
      Misty WheelerSep 14, 2025
      If the shunt field current is too low: * Check the motor shunt field and associated circuitry for a loose connection or a broken wire. Repair accordingly. * Check the motor rating, as the shunt field may be connected for incorrect voltage. * Replace BR1 or the control board, as there may be a Shunt Field Bridge BR1 failure.
  • G
    Gregory MontoyaNov 17, 2025
    Why won't my Fincor 2602 Controller motor start?
    • S
      Sierra SimpsonNov 17, 2025
      The motor may not start due to several reasons: * The AC line may be open. Ensure the rated AC line voltage is applied to the controller. * Operator controls may be inoperative or connected incorrectly; repair accordingly. * There might be an open circuit between Connectors E1 and E2 in 1/6 - 3 HP controllers. A wire jumper or switch must connect E1 to E2. * The controller may not be reset. Initiate a Stop command and then a Start command. * The controller may not be enabled; ensure +24 VDC is applied to Terminal TB2- 8. * There might be a loss of speed reference signal. Check for a 0 - 10 VDC, 4 - 20 mA, or 0 - 5 VDC speed reference signal, as applicable. * The controller may not be adjusted correctly. Turn the ACCEL and CUR LIM potentiometers fully clockwise (100%). * Th...

Summary

Safety Warnings

General Safety Precautions

Essential safety guidelines for operating and servicing Fincor drive equipment.

Installation

Installation Guidelines and Requirements

Guidelines for controller mounting, atmosphere, construction, protection, grounding, and wiring.

Controller Installation Procedure

Step-by-step instructions for installing the controller unit, including jumper settings.

Operation

Power On;Off and Run;Stop Procedures

How to energize, run, and stop the motor using the controller.

Motor Reversing and Inoperative Motor

Procedures for reversing motor rotation and troubleshooting inoperative motors.

Maintenance and Repair

Adjustment Procedures

Instructions for adjusting acceleration, deceleration, speed, and current limit settings.