EasyManua.ls Logo

Finkbeiner EHB702 - Electrical Connection and Phasing

Default Icon
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
Walter Finkbeiner GmbH
Alte Poststrasse 9/11
72250 Freudenstadt / Germany
www.finkbeiner.eu
20 / 56
PB-BA-EHB702-102GB
22.02.2011
5.4 Electrical connection
If lift has been delivered without power supply plug (country-specific) mount appropriate plug to
power supply cable.
WARNING
Hazard of material damage by wrong operation voltage.
Take care that lift is connected to the prescribed power supply (see manufac-
turer nameplate).
Connect power supply plug into appropriate mains.
Clockwise phase sequence required. Turning direction if incorrect can be changed as follows:
Unplug lift from mains, open plug and change phase connections L1 and L2. Close plug correctly
again.
If the lift is used at some other location or at use of an electrical extension cable the phase se-
quence may be incorrect and needs to be checked again.