Inspection and maintenance
Walter Finkbeiner GmbH
Alte Poststrasse 9/11
72250 Freudenstadt / Germany
www.finkbeiner.eu
32 / 56
PB-BA-EHB702-102GB
22.02.2011
8.1.4 Oil change
An oil change should be performed at least every 2 years.
Quantity required: approx. 9 liter
Use following oil: HLP ISO-VG 32, filtrated to 5 Micrometer.
Lower the lift completely to the floor.
Drain the oil tank.
Re-fill oil up to the marking (see decal on oil tank).
When changing the oil regard no dirt or water can enter into the hydraulic system of the lift.
Information
If the lift is used in multi-shift operation, in wet surroundings or under high UV radiation
an oil change every year is recommended.
Not sufficient filtered oil may cause malfunction or defects at hydraulic components.
Environment information
Environmental hazard through hydraulic oil leakages.
Observe the appropriate environmental regulations when disposing of hydraulic oil.
8.2 Inspection and maintenance by customer service
Yearly
Visual and function inspection by a competent expert with entry in the Inspection Log.
Differing maintenance intervals to be regarded according the country-specific regulations.