)HDWXUHVDQG2SWLRQV 3URGXFW'HVFULSWLRQ
068'31$ 
• EIA-232 Printer/PC interface (variable baud rate)
• 80-character LCD display (backlit)
• Real-time clock/calendar with daylight savings time control
• History file with 1,000 event capacity
• Advanced fire technology features:
✓ Automatic drift compensation
✓ Maintenance alert
✓ Detector sensitivity test capability (NFPA 72 compliant)
✓ Automatic device type-code verification
✓ Point trouble identification
• Waterflow selection per module point
• Alarm verification selection per detector point
• Walktest, silent or audible
• PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant)
• Silence inhibit timer option per NAC
• Autosilence timer option per NAC
• Continuous, March Time, Temporal or California code for main circuit board
NACs with two-stage capability
• Selectable strobe synchronization per NAC
• Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules,
AFM annunciators or LCD-80F Remote annunciator
• Auto-program (learn mode) reduces installation time. Reports two devices set to
the same address
• Password and key-protected nonvolatile memory
• User programmable password
• Fully programmable from local keypad or optional keyboard
• Upload/Download (local or remote) of program and data via integral DACT
• SLC operates up to 10,000 ft. (3,000 m) with twisted, shielded wire or 3,000 ft
(900 m) with untwisted, unshielded wire
• Compatible with Fire•Lite’s newer series devices
✓ CP350, CP355: addressable Ionization Smoke Detector
✓ SD350(T), SD355(T), AD355: addressable Photo Smoke Detector (T= with
Thermal Sensor)
✓ H350(R), H355(R), H355HT: Fast Response Heat Detector (R=Rate-of-Rise
option, HT=High Temperature 190
R
F)
✓ D350P(R): addressable Photo Duct Detector (R=alarm relay option)
✓ B501BH & B501BHT Sounder Base
✓ B224RB Relay Base
✓ B224BI Isolator Base
✓ MMF-300: Monitor Module
✓ MMF-300-10: Monitor Module (10 Input Class B or 5 Input Class A)
✓ MDF-300: Dual Monitor Module (uses two consecutive SLC addresses)
✓ MMF-301: Miniature Monitor Module
✓ MMF-302: 2-wire Detector Module
✓ MMF-302-6: 2-wire Detector Module (6 Input Class B or 3 Input Class A)
✓ CMF-300: Control Module
✓ CMF-300-6: Control Module (6 Output Class B or 3 Output Class A)
✓ CRF-300: Relay Module
✓ CRF-300-6: Relay Module (6 Form-C relays)
✓ BG-12LX: Manual Pull Station
✓ I300: Isolator Module