TEST SETTINGS
LONG LEAD
This is used when appliances and power cords exceeding 1m in length are being
tested. With this function, the MemoryPAT-Blu can test appliances and power
cords up to 50m in length.
INSULATION RESISTANCE TEST VOLTAGE
The MemoryPAT-Blu uses a 500V test voltage for the Insulation Resistance test.
The user can select to use a 250V test voltage for this when testing surge
protected appliances.
SELF TEST
The MemoryPAT-Blu monitors the test voltages and currents during a test and
reports any problems to the user.
ACCESSORIES
The following accessories are supplied with the MemoryPAT-Blu:
CHARGER
Wall charger and USB lead for charging the MemoryPAT-Blu’s built in batteries
or to operate the tester from the mains. The USB lead can also be used to
connect the MemoryPAT-Blu to a USB port of a PC to download test results.
SHORT IEC LEAD
This allows mains extension leads to be connected to the IEC socket of the
MemoryPAT-Blu for testing.
SAMPLE FORMS
An “Equipment Register” and a “Equipment Test Record” form is included.
These can be copied and used as often as required. The user manual refers to
this under the relevant sections.