Camera web interface
10
3. In the Folder box, type the path to the folder where you want to save the notifications.
This can be useful if you have multiple cameras connected to the same FTP server.
4. In the User and Password boxes, type the credentials for FTP access.
5. Click Apply.
10.6.3 Scheduler
Use the Scheduler page to configure what actions to run, and when to run them. The re-
sult of an action can be sent by e-mail or to a folder on an FTP server.
Available actions are:
• E-mail image
Send the image with overlay graphics.
• E-mail result
Send a list of the active measurements and their respective temperatures.
• Save image on FTP
Send the image with overlay graphics to an FTP server.
To schedule actions, follow this procedure:
1. In the navigation pane, click Scheduler.
2. Click the check boxes to select which Scheduled actions to use.
3. In the schedule, click the Active check box for the days that the action will run:
• To run the action once a day at a certain time, also click Once and then set an Ac-
tion Time.
• To run the action several times a day, also click Repeat and then set a time Inter-
val, a Start action time, and an End action time.
4. Click Apply.
To configure delivery to FTP, follow this procedure:
1. In the FTP Server box, type the IP address of the FTP server.
2. In the FTP User and FTP Password boxes, type the credentials for the FTP access.
3. Click Apply.
To configure delivery by e-mail, follow this procedure:
1. In the Recipient e-mail box, type the e-mail address of the recipient.
2. In the Mail server box, type the IP address of the sending mail server.
3. In the Sender e-mail box, type the e-mail address of the sender.
4. If the sending mail server requires a login (mail server authentication), select the Au-
thenticate mail check box, and then type the credentials in the User and Password
boxes.
5. Click Apply.
10.6.4 MQTT
It is possible to setup a publish/subscribe messaging transport using the MQTT protocol
(MQ Telemetry Transport). Topics that are available for subscription are shown in the
Topic subscriptions section. Note that the corresponding measurement functions and
alarms must be defined and active, or no information will be published.
Follow this procedure:
1. In the navigation pane, click MQTT.
2. Click the Enable MQTT check box.
3. Type the Broker host address and the TCP Broker Port used for the subscription
transport.
4. Type the User and Password to login to the broker.
5. Select preferred Temperature unit in the list; Celsius (C), Fahrenheit (F), or Kelvin (K).
6. Select preferred Output format in the list; Json or Text.
7. Click Apply.