Technical data14
Image presentation modes
Image modes
• IR image
◦ TI Basic NFPA fire-fighting mode
◦ Black-and-white fire-fighting mode
◦ Fire mode
◦ Search-and-rescue mode
◦ Heat detection mode
• Thumbnail gallery
Measurement
Object temperature range
• –20°C to +150°C (–4°F to +302°F)
• 0°C to +650°C (+32°F to +1202°F)
Accuracy ±4°C (±7.2°F) or ±4% of reading, for ambient tem-
perature 10°C to 35°C (+50°F to 95°F)
Measurement analysis
Spotmeter
1
Automatic hot detection Heat detection mode (the hottest 20% of the of
scene is colorized)
Isotherm Yes, according to NFPA
Set-up
Set-up commands Local adaptation of units, date and time formats
Languages English
Storage of images
Image storage Standard JPEG
Storage media Internal flash memory
Image storage capacity 200 files in total
NOTE
The number of files is co-dependent on the
number of saved video clips.
Image storage mode IR only
File formats Standard JPEG
Image annotations
Report generation Separate software (FLIR Tools)
Video recording in camera
Non-radiometric IR video recording
MPEG-4 to internal flash memory
Storage capacity 200 files in total, with a maximum duration of 5 mi-
nutes each.
NOTE
The total number of files is co-dependent on
the number of saved images.
Video streaming
Non-radiometric IR video streaming
Uncompressed colorized video using USB
USB
USB USB Mini-B
#T559946; r. BA/41926/41970; en-US
59