Operation
11
11.1.1.1 General
Charge the battery for 4 hours before starting the camera for the first time, or until the blue
battery condition LED glows continuously.
11.1.1.2 Procedure
Follow this procedure:
1. Put the battery in the standalone battery charger.
2. Connect the power supply cable plug to the connector on the standalone battery
charger.
3. Connect the power supply mains-electricity plug to a mains socket.
4. Disconnect the power supply cable plug when the blue battery condition LED glows
continuously.
11.2 Turning on and turning off the camera
• Push the on/off button to turn on the camera.
• Push and hold the on/off button for more than 3 seconds but less than 10 seconds to
put the camera into standby mode. The camera then automatically turns off after 6
hours.
• Push and hold the on/off button for more than 10 seconds to turn off the camera.
11.3 Basic mode
The camera features one camera mode: Basic mode. This is a multipurpose mode for the
initial fire attack with life-saving operations and control of the fire. The camera automati-
cally switches between the high-sensitivity range and the low-sensitivity range, to maintain
an optimal infrared image while at the same time maintaining a safe and consistent heat
colorization of the fire scene. This automatic switching of ranges occurs when objects with
a temperature above 150°C (302°F) enter the field of view of the camera.
• Automatic range.
• Colorization of heat: +150 to +650°C (+302 to +1202°F).
• High-sensitivity range: –20 to +150°C (–4 to +302°F).
• Low-sensitivity range: 0 to +650°C (+32 to +1202°F).
#T810170; r. AE/41948/41948; en-US
20