Location I
OIL LEAKAGE
Weep holes and locations are identified on the illustrations on Pages 66–67.
Fluid
Likely problem Other possible symptoms
Maintenance
procedure
Kit or parts needed
Qty. Temp.
Occasional
drip
Warm
Loose manifold
mounting screws
Retorque manifold mounting screws as
described in your pump manual.
Worn or pinched
o-rings
Service o-rings as described in your
pump manual.
Misaligned end bells F
Location J
OIL LEAKAGE
Weep holes and locations are identified on the illustrations on Pages 66–67.
Fluid
Likely problem Other possible symptoms
Maintenance
procedure
Kit or parts needed
Qty. Temp.
Occasional
drip
Warm
Loose pilot valve
mounting screws
Retorque pilot valve mounting screws as
described in your pump manual.
Worn o-rings
Service o-rings as described in your
pump manual.
Location K
OIL LEAKAGE
Weep holes and locations are identified on the illustrations on Pages 66–67.
Fluid
Likely problem Other possible symptoms
Maintenance
procedure
Kit or parts needed
Qty. Temp.
Occasional
drip
Warm
Loose shift valve
mounting screws
Retorque shift valve mounting screws as
described in your pump manual.
Worn o-rings
Service o-rings as described in your
pump manual.
74 | M-376 © Flow International Corporation