EasyManua.ls Logo

Flow 94K HYPERPRESSURE - Page 74

Default Icon
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Location I
OIL LEAKAGE
Weep holes and locations are identified on the illustrations on Pages 66–67.
Fluid
Likely problem Other possible symptoms
Maintenance
procedure
Kit or parts needed
Qty. Temp.
Occasional
drip
Warm
Loose manifold
mounting screws
—
Retorque manifold mounting screws as
described in your pump manual.
Worn or pinched
o-rings
—
Service o-rings as described in your
pump manual.
Misaligned end bells — F —
Location J
OIL LEAKAGE
Weep holes and locations are identified on the illustrations on Pages 66–67.
Fluid
Likely problem Other possible symptoms
Maintenance
procedure
Kit or parts needed
Qty. Temp.
Occasional
drip
Warm
Loose pilot valve
mounting screws
—
Retorque pilot valve mounting screws as
described in your pump manual.
Worn o-rings —
Service o-rings as described in your
pump manual.
Location K
OIL LEAKAGE
Weep holes and locations are identified on the illustrations on Pages 66–67.
Fluid
Likely problem Other possible symptoms
Maintenance
procedure
Kit or parts needed
Qty. Temp.
Occasional
drip
Warm
Loose shift valve
mounting screws
—
Retorque shift valve mounting screws as
described in your pump manual.
Worn o-rings —
Service o-rings as described in your
pump manual.
74 | M-376 © Flow International Corporation
94K HYPERPRESSURE INTENSIFIER

Table of Contents