Location L
OIL LEAKAGE
Weep holes and locations are identified on the illustra
-
tions on Pages 66–67.
Fluid
Likely problem Other possible symptoms
Maintenance
procedure
Kit or parts needed
Qty. Temp.
Occasional
drip
Warm
Loose shift sensor
mounting screws
Retorque shift sensor mounting screws as
described in your pump manual.
Worn o-rings
Service o-rings as described in your
pump manual.
Location M
OIL LEAKAGE
Weep holes and locations are identified on the illustra
-
tions on Pages 66–67.
Fluid
Likely problem Other possible symptoms
Maintenance
procedure
Kit or parts needed
Qty. Temp.
Occasional
drip
Warm Worn o-rings A,F
Low-pressure seal kit
013157 or 020080-1
© Flow International Corporation M-376 | 75