surfaces with a dry cloth; ensure cloth is damp.
The coupling must be selected to comply with 94/9/EC
and correct alignment must be maintained.
1.6.4.6
Preventing
leakage
The pump shall only be used to handle liquids
for which it has been approved to have the correct
corrosion resistance.
Avoid entrapment of liquid in the pump and
associated piping due to closing of suction and
discharge valves, which could cause dangerous
excessive pressures to occur if there is heat input to
the liquid. This can occur if the pump is stationary or
running.
Bursting of liquid containing parts due to freezing
must be avoided by draining or protecting the pump
and ancillary systems.
Where there is the potential hazard of a loss of a seal
barrier fluid or external flush, the fluid shall be
monitored.
If leakage of liquid to atmosphere can result in a
hazard, then a liquid detection device shall be
installed.
1.6.4.7
Maintenance
to
avoid
the
hazard
CORRECT MAINTENANCE IS REQUIRED TO
AVOID POTENTIAL HAZARDS WHICH GIVE A
RISK OF EXPLOSION
The responsibility for compliance with
maintenance instructions is with the plant owner
or operator.
To avoid potential explosion hazards during
maintenance, the tools, cleaning and painting
materials used must not give rise to sparking or
adversely affect the
ambient conditions.
Where there
is a risk from such tools or materials, maintenance
must be conducted in a safe area.
A maintenance plan and schedule shall be adopted.
(See section 6,
Maintenance
)
1.7
Warning
labels