24
0
0.01
0.02
0.03
0.04
0.05
0.06
0.07
A B F1 F2
0.01
0.02
0.03
0.04
0.05
0.06
0.07
28 30 32 34 36 38 402624222018160 2 4 6 8 10 12 14
C C
Distance Over Motor Feet (in)
Pump
Hub
Clock
Readings
(in)
EXAMPLE 1
X-X
Y-Y
VERTICAL HORIZONTAL
TIR FOR TOP AND BOTTOM TIR FOR SIDE TO SIDE
A = - 0.034" Therefore Plot A above - 0.007” A = + 0.014" Therefore A above + 0.017”
B = + 0.024" Therefore Plot B above + 0.012” B = - 0.008" Therefore B above - 0.004”
MOTORS ALTERED AS FOLLOWS: MOTOR TO BE MOVED TO FAR SIDE
F1 Add 0.002" of Shims F1 = 0.002" and F1 = 0.0155".
F2 remove 0.0205" of Shims

Table of Contents