Logix 3400MD Digital Positioner FCD LGENIM3404-00 – 9/09
28
Fieldbus
Block
Index
Fieldbus Variable
Name
Transducer
Block
Fieldbus
Datatypes
Logix Positioner
R/W Description
Register Type
Fix
Pt
Rd
Variable Name
54 HOURS_SINCE_RESET XDTB_MAIN FLOAT 138 U_LONG /10 Reset_Hours R Status, System, Time Elapsed,
Mem Reset
55 HOURS_LIFETIME XDTB_MAIN FLOAT 139 U_LONG /10 Lifetime_Hours R Status, System, Time Elapsed,
Lifetime
86 ERROR_HIST XDTB_TECH ARRAY 140 U_CHAR NO ErrorHist [16] R History of the last error/blink
codes
Signature Parameters
56 SIG_START XDTB_MAIN FLOAT 142 S_INT /100 SIGstart NRW Config, Signature, Starting
Command in %
57 SIG_STOP XDTB_MAIN FLOAT 143 S_INT /100 SIGstop NRW Config, Signature, Stopping
Command in %
58 SIG_RATE XDTB_MAIN FLOAT 144 U_INT /100 SIGtime NRW Time that a Signature takes to
complete a ramp cycle
59 SIG_HOLD XDTB_MAIN FLOAT 145 U_INT /100 SIGhold NRW Time to continue to log
signature data after reaching
SIG_STOP
61 SIG_FLAGS XDTB_MAIN BIT_STRING 146 U_CHAR NO SIGflags NRW Signture status and command
flags
60 SIG_INDEX XDTB_MAIN UNSIGNED 16 147 U_INT NO ReadSigIndex NRW Index into the Signature Data
Array
88-113 SIG_DATAn XDTB_TECH ARRAY 148 S_INT [24] /100 SigData R Signature Data Array
System Setup & Special Diagnostics Parameters
33 USER_INTERFACE_
INSTANT
XDTB_TECH BIT_STRING 36 U_INT NO UI_Instant R Curent hardware DIP switch
and GAIN control seetings - not
applied to control algorythms.
34 USER_INTERFACE_
ACTIVE
XDTB_TECH BIT_STRING 37 U_INT NO UI_Saved RW Setup button and DIP switch
setting currently applied to
control algorythms
24 TEST_MODE XDTB_MAIN BIT_STRING 32 U_CHAR NO control_
disable_flg
RW Turns on and off spceial
diagnostic capabilities
62 TRAVEL_ACCUM_UNITS XDTB_MAIN UNSIGNED 8 150 U_CHAR NO TravelUnits SRW Setup, Units, Travel Distance
63 PRESSURE_UNITS XDTB_MAIN UNSIGNED 8 151 U_CHAR NO PressUnits SRW Setup, Units, Pressure
64 INTERNAL_TEMP_UNITS XDTB_MAIN UNSIGNED 8 152 U_CHAR NO TempUnits SRW Setup, Units, Temperature
65 XD_FSTATE_OPT XDTB_MAIN UNSIGNED 8 153 U_CHAR NO Fail_mode SRW
66 ELECTRONICS_SN XDTB_MAIN VISIBLE_
STRING
155 U_CHAR NO ESN [8] NR Electronics Serial Number, used
for initial PD tag
67 SOFTWARE_VER_MAJOR XDTB_MAIN UNSIGNED 16 156 U_INT NO ESR_Major NR Software Revision Major
68 SOFTWARE_VER_MINOR XDTB_MAIN UNSIGNED 16 157 U_INT NO ESR_Minor NR Software Revision Minor
69 SOFTWARE_DATE_CODE XDTB_MAIN VISIBLE_
STRING
158 STRING NO ESR_Build [6] SRW Embedded Software Revision
Date Stamp
73 FB_POSITION_FILTER XDTB_TECH UNSIGNED 16 162 U_INT NO FB_Depth SRW Setup, Dampening, Position,
Depth
75 LOAD_EE_DEFAULTS XDTB_TECH UNSIGNED 8 173 U_CHAR NO EEmode RW Test, FRAM, Mode Setting
System Setup & Special Diagnostc Fieldbus Only Parameters