Title Page
Introduction........................................................................................................ 1
How to Contact Fluke ........................................................................................ 1
Precautions and Safety Information................................................................... 2
Specifications..................................................................................................... 4
General Specifications................................................................................... 4
Category Ratings and Usage.......................................................................... 5
Electrical Measurement Specifications ......................................................... 5
Insulation Resistance (R
ISO
) ...................................................................... 5
Continuity (R
LO
)........................................................................................ 6
Loop Tests (Z
I
).......................................................................................... 6
RCD/FI Tests (
T, I
N) ............................................................................. 7
Earth Tests (R
E
)......................................................................................... 8
AC Voltage Measurement (V) .................................................................. 8
Continuity Testing (R
LO
) ......................................................................... 8
Insulation Resistance Measurement (R
ISO
) ............................................. 9
No Trip and Hi Current Modes RCD/FI ................................................... 9
Prospective Earth Fault Current Test (PSC/I
K
).............................................. 10
RCD Testing.................................................................................................. 10
RCD Types Tested .................................................................................... 10
Test Signals ............................................................................................... 10
Tripping Speed Test (
T).......................................................................... 11
Maximum Trip Time................................................................................. 11
RCD/FI-Tripping Current Measurement/Ramp Test (I
N
)...................... 11
Earth Resistance Test (R
E
)........................................................................... 12
Phase Sequence Indication ............................................................................ 12
Mains Wiring Test......................................................................................... 12
Operating Ranges and Uncertainties per EN 61557...................................... 13
Operating Uncertainties per EN 61557 ......................................................... 14
Equipment Requirements................................................................................... 15
Basic Maintenance............................................................................................. 16
How to Clean the Tester ................................................................................ 16
How to Test and Replace the Batteries.......................................................... 16
How to Test and Replace the Fuse ................................................................ 17
Performance Tests.............................................................................................. 18
Backlight Test................................................................................................ 18
LCD Test ....................................................................................................... 18

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1653B and is the answer not in the manual?

Fluke 1653B Specifications

General IconGeneral
Insulation Test Voltage50 V, 100 V, 250 V, 500 V, 1000 V
Loop and Line Resistance0.01 Ω to 1999 Ω
Loop/Line Resistance0.01 Ω to 1999 Ω
Frequency45 Hz to 65 Hz
Resistance Measurement Range0.01 Ω to 1999 Ω
Loop Impedance Measurement Range0.01 Ω to 1999 Ω
Power Supply6 x 1.5 V AA batteries
AC Voltage Range500 V
DC Voltage Range500 V
Insulation Resistance Range0.01 MΩ to 1000 MΩ
Prospective Earth Fault Current (PEFC)0 A to 20 kA
Prospective Short Circuit Current (PSC)0 A to 20 kA
RCD Trip Time300 ms
RCD Trip Current10 mA to 1000 mA
DisplayDigital
Safety CategoryCAT III 500 V, CAT IV 300 V
RCD Trip Time Measurement Range10 ms to 2000 ms
Dimensions10 cm x 25 cm x 12.5 cm
Safety StandardsEN61557