EasyManua.ls Logo

Fluke 1736 - Page 84

Fluke 1736
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1736/1738
Users Manual
74
iFlex Probe Specifications
Measuring range
iFlex 1500-12 ........................................ 1 to 150 A ac / 10 to 1500 A ac
iFlex 3000-24 ........................................ 3 to 300 A ac / 30 to 3000 A ac
iFlex 6000-36 ........................................ 6 to 600 A ac / 60 to 6000 A ac
Nondestructive current .......................... 100 kA (50/60 Hz)
Intrinsic Error at reference
condition
[1]
............................................. ±0.7% of reading
Accuracy 173x + iFlex
iFlex 1500-12 & iFlex 3000-24 .............. ±(1 % of reading + 0.02 % of
range)
iFlex 6000-36 ........................................ ±(1.5 % of reading + 0.03 % of
range)
Temperature Coefficient over operating temperature range
iFlex 1500-12 & iFlex 3000-24 .................. 0.05 % of reading / °C (0.09 %
of reading / °F)
iFlex 6000-36 ............................................ 0.1 % of reading / °C (0.18 %
of reading / °F)
Positioning error with position of conductor in the probe window (see
Figure 14).
iFlex1500-12, iFlex3000-24
iFlex6000-36
Probe
Window A
±(1 % of reading + 0.02 %
of range)
±(1.5 % of reading + 0.03
% of range)
Probe
Window B
±(1.5 % of reading + 0.02
% of range)
±(2.0 % of reading + 0.03
% of range)
Probe
Window C
±(2.5 % of reading + 0.02
% of range)
±(4 % of reading + 0.03 %
of range)
External magnetic field rejection in reference to external
current (with cable >100 mm from the head-coupling
and r-coil) .................................................. 40 dB
Phase shift ................................................ < ±0.5°
hcf057.eps
Figure 14. iFlex Probe Window
Bandwidth ................................................... 10 Hz to 23.5 kHz
Frequency derating ..................................... I x f 385 kA Hz
Working Voltage .......................................... 1000 V CAT III, 600 V CAT IV
[1] Reference Condition:
Environmental: 23 °C ±5 °C, no external electrical/magnetic field, RH 65 %
Primary conductor in center position
iFlex1500-12: 88mm
iFlex3000-24: 185mm
iFlex6000-36: 282mm
C
B
A
1/31/31/3