1736/1738
Users Manual
76
Phase shift
<40 mA ............................................... unspecified
40 mA to 400 mA ................................ < ± 1.5°
400 mA to 40 A ................................... < ± 1°
Temperature Coefficient over
operating temperature range .................. 0.015 % of reading / °C
0.027 % of reading / °F
Influence of adjacent conductor .............. 15 mA/A (@ 50/60 Hz)
Influence of conductor position
in jaw opening ......................................... ±0.5 % of reading (@ 50/60 Hz)
Bandwidth ............................................... 10 Hz to 2.5 kHz
Working Voltage ..................................... 600 V CAT III, 300 V CAT IV
[1] Reference Condition:
Environmental: 23 °C ±5 °C, no external electrical/magnetic field, RH 65 %
Primary conductor in center position
Size (H x W x L) ...................................... 110 mm x 50 mm x 26 mm
(4.33 in x 1.97 in x 1.02 in)
Maximum conductor size ........................ 15 mm (0.59 in)
Output cable length ................................. 2 m (6.6 ft)
Weight ..................................................... 190 g (6.70 oz)
Material ................................................... Case ABS and PC
Output cable: TPR/PVC
Temperature operating ........................... -10 °C to +55 °C
(-14 °F to 131 °F)
Temperature, non-operating ................... -20 °C to +70 °C
(-4 °F to 158 °F)
Relative Humidity, operating ................... 15 % to 85 % non-condensing
Max Operating Altitude .......................... 2000 m (6,500 ft)
up to 4000 m (13,000 ft) derate
to 600 V CAT II/300 V CAT IV
Max Storage Altitude ............................. 12 km (40,000 ft)
Warranty ................................................. 1 year
Authorised Distributor
POWERPOINT ENGINEERING Ltd.
Unit B6, National Enterprise Park
Portlaoise, Co. Laois R32 HH36
t: (057) 866 2162 f: (057) 866 2164
e: sales@fluke-ireland.ie
w: www.fluke-ireland.ie

Table of Contents

Other manuals for Fluke 1736

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1736 and is the answer not in the manual?

Fluke 1736 Specifications

General IconGeneral
Product typeThree phase power measurement logger
Cable lock slot typeKensington
International Protection (IP) codeIP50
Operating altitude0 - 4000 m
Non-operating altitude0 - 12000 m
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)10 - 95 %
Built-in displayYes
Display diagonal4.3 \
Touchscreen typeResistive
Display resolution480 x 272 pixels
Display technologyTFT
Efficiency68.2 %
Battery life4 h
Charging time6 h
Battery voltage3.7 V
Input frequency50/60 Hz
Battery capacity9.25 Wh
Power consumption (max)50 VA
Battery life (power save mode)5.5 h
Weight and Dimensions IconWeight and Dimensions
Depth55 mm
Width198 mm
Height167 mm
Weight1100 g
Power adapter weight400 g
Power supply dimensions (WxDxH)130 x 45 x 130 mm