EasyManua.ls Logo

Fluke 1738/B - Page 79

Fluke 1738/B
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power Logger
Electrical Specifications
73
iFlex Probe Specifications
Measuring range
iFlex 1500-12 ......................................................1 to 150 A ac / 10 to 1500 A ac
iFlex 3000-24 ......................................................3 to 300 A ac / 30 to 3000 A ac
iFlex 6000-36 ......................................................6 to 600 A ac / 60 to 6000 A ac
Nondestructive current ........................................100 kA (50/60 Hz)
Intrinsic Error at reference condition
[1]
................. ±0.7 % of reading
Accuracy 173x + iFlex
iFlex 1500-12 & iFlex 3000-24 ........................ ±(1 % of reading + 0.02 % of range)
iFlex 6000-36 .................................................. ±(1.5 % of reading + 0.03 % of range)
Temperature Coefficient over operating temperature range
iFlex 1500-12 & iFlex 3000-24 ............................0.05 % of reading / °C (0.09 % of reading / °F)
iFlex 6000-36 ......................................................0.1 % of reading / °C (0.18 % of reading / °F)