Power Logger
Electrical Specifications
75
Working Voltage......................................................1000 V CAT III, 600 V CAT IV
[1] Reference Condition:
Environmental: 23 °C ±5 °C, no external electrical/magnetic field, RH 65 %
Single primary conductor in center position
Transducer length
iFlex 1500-12 ......................................................305 mm (12 in)
iFlex 3000-24 ......................................................610 mm (24 in)
iFlex 6000-36 ......................................................915 mm (36 in)
Transducer cable diameter .....................................7.5 mm (0.3 in)
Minimum bending radius .........................................38 mm (1.5 in)
Output cable length
iFlex 1500-12 ......................................................2 m (6.6 ft)
iFlex 3000-24 & iFlex 6000-36 ............................3 m (9.8 ft)
Weight
iFlex 1500-12 ......................................................115 g
iFlex 3000-24 ......................................................170 g
iFlex 6000-36 ......................................................190 g
Material
Transducer cable ................................................TPR
Coupling ..............................................................POM + ABS/PC
Output cable........................................................TPR/PVC
Operating Temperature ..........................................-20 °C to +70 °C (-4 °F to 158°F) temperature of conductor under test shall not exceed 80°C (176°F)
Storage temperature ...............................................-40 °C to +80 °C (-40 °F to 176 °F)
Operating relative humidity .....................................15 % to 85 % noncondensing
IP Rating .................................................................IEC 60529:IP50
Operating Altitude ...................................................2000 m (6500 ft) up to 4000 m (13 000 ft) derate to 1000 V CAT II/600 V CAT III/300 V CAT IV
Storage Altitude.......................................................12 km (40 000 ft)
Warranty..................................................................1 year