1736/1738
Users Manual
12
How to Charge Battery
The Logger also operates on an internal rechargeable
Lithium-ion battery. After you unpack and inspect the
Logger, fully charge the battery before first use.
Afterwards, charge the battery when the battery icon on
the screen indicates that power is low. The battery
automatically charges when the Logger is connected to the
mains power. The Logger continues to charge when
turned off and connected to mains power.
Note
The battery charge is faster when the Logger is
turned off.
To charge the battery:
1. Connect the mains cord to the ac input socket on the
power supply.
2. Fit the power supply to the Logger or use the dc power
cord to connect the power supply to the Logger.
3. Connect to mains power.
Caution
To prevent damage to the Product:
Do not leave batteries unused for extended
periods of time, either in the product or in
storage.
When a battery has not been used for six
months, check the charge status and
charge the battery as appropriate.
Clean battery packs and contacts with a
clean, dry cloth.
Battery packs must be charged before use.
After extended storage, it can be necessary
to charge and discharge a battery pack to
obtain maximum performance.
Dispose properly.
Note
Li-ion batteries keep a charge longer if stored
at room temperature.
The clock resets when the battery is
completely discharged.
When the Logger shuts off because of low
battery, enough battery capacity is available to
back up the real-time clock for up to 2 months.

Table of Contents

Other manuals for Fluke 1738

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1738 and is the answer not in the manual?

Fluke 1738 Specifications

General IconGeneral
Product typeThree phase power measurement logger
Cable lock slot typeKensington
International Protection (IP) codeIP50
Operating altitude0 - 4000 m
Non-operating altitude0 - 12000 m
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)10 - 95 %
Built-in displayYes
Display diagonal4.3 \
Touchscreen typeResistive
Display resolution480 x 272 pixels
Display technologyTFT
Efficiency68.2 %
Battery life4 h
Charging time6 h
Battery voltage3.7 V
Input frequency50/60 Hz
Battery capacity9.25 Wh
Power consumption (max)50 VA
Battery life (power save mode)5.5 h
Weight and Dimensions IconWeight and Dimensions
Depth55 mm
Width198 mm
Height167 mm
Weight1100 g
Power adapter weight400 g
Power supply dimensions (WxDxH)130 x 45 x 130 mm