EasyManuals Logo

Fluke 17B MAX User Manual

Fluke 17B MAX
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
Digital Multimeters
TL31 Test Leads
15
Test Small Components in Circuit
To test small components in the circuit, see Figure 9:
1. Push up from the bottom of the protective caps with
thumb to remove both caps.
2. Fluke recommends that you clamp the caps on the test
cables close to DMM.
3. Connect the bare tips to small components on the
circuit to do the measurement.
4. When you finish the test, reinstall the protective caps.
Figure 9. Test Small Components in Circuit
Test CAT III Applications
For CAT III applications, see Figure 10:
1. Twist the protective caps and then push them firmly
onto the lead body. The end of the probe should come
out of the cap end.
WWarning
To prevent possible personal injury, do not push
the protective cap onto the lead body with your
thumb.
2. When you finish the test, push the cap back up to hide
the tip to reinstall the protective caps.
Figure 10. Probe Position for CAT III Applications
1
32
4
1 2 3