Digital Multimeters
Specifications
19
AC and DC Current
Burden voltage (typical value)
AC/DC Current μA: 100 μV / μA
AC/DC Current mA: 2 mV/mA
AC/DC Current A: 0.03 V/A
Function Range Resolution
Accuracy
15B MAX 17B MAX
AC Current μA
(40 Hz to 400 Hz)
g
400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3 1.5 % + 3
AC Current mA
(40 Hz to 400 Hz)
l
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3 1.5 % + 3
AC Current A
(40 Hz to 400 Hz)
a
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3 1.5 % + 3
DC Current μA
e
400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3 1.5 % + 3
DC Current mA
n
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3 1.5 % + 3
DC Current A
b
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3 1.5 % + 3