EasyManuals Logo

Fluke 17B MAX User Manual

Fluke 17B MAX
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
15B MAX/17B MAX
Users Manual
20
Diode Test, Temperature, Resistance,
Capacitance, Frequency, and Duty Cycle
Function Range Resolution
Accuracy
15B MAX 17B MAX
Diode Test
[1]
O
2.000 V 0.001 V 10 % 10 %
Te m p e r a t u r e
[6]
T
50.0 °C to 400.0 °C
C to 50.0 °C
-55.0 °C to 0 °C
0.1 °C NA
2% +C
C
9% +C
Resistance (Ohms)
[2]
Ω
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
Capacitance
[3]
E
40.00 nF
400.0 nF
4.000
μF
40.00
μF
400.0
μF
2000
μF
0.01 nF
0.1 nF
0.001
μF
0.01
μF
0.1
μF
1
μF
2% + 5
2% + 5
5% + 5
5 % + 5
5% + 5
5% + 5
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5

Other manuals for Fluke 17B MAX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 17B MAX and is the answer not in the manual?

Fluke 17B MAX Specifications

General IconGeneral
BrandFluke
Model17B MAX
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals