Specifications
Electromagnetic Immunity
10
129
Electromagnetic Immunity
The Fluke 19xC-2x5C series, including standard accessories, conforms with the EEC directive 2004/108/EC for EMC
immunity, as defined by EN-61326-1:2006, with the addition of the following tables.
Scope Mode (10 ms/div): Trace disturbance with VPS210 voltage probe shorted
Table 12
No visible disturbance E = 3V/m
Frequency range 10 kHz to 20 MHz 2 mV/div to 100 V/div
Frequency range 20 MHz to 100 MHz 200 mV/div to 100 V/div
Frequency range 100 MHz to 1 GHz
Frequency range 1.4 GHz to 2.0 GHz
500 mV/div to 100 V/div
*)
2 mV/div to 100 V/div
(*) With the 20 MHz Bandwidth Filter switched on: no visible disturbance.
With the 20 MHz Bandwidth Filter switched off: disturbance is max 2 div.
Table 13
No visible disturbance E = 1V/m
Frequency range 2.0 GHz to 2.7 GHz 2 mV/div to 100 V/div
Table 14
Disturbance less than 10% of full scale E = 3V/m
Frequency range 20 MHz to 100 MHz 10 mV/div to 100 mV/div
Test Tool ranges not specified in tables 12, 13 and 14 may have a disturbance of more than 10% of full scale.