353/355
Users Manual
18
Standards and Agency Approval Specifications
Design
Standards and
Compliance
EN61010-032 CAT IV 600 V,
IEC/EN 61326-1:1997
Agency
Approvals
P, ), ;, ~
N10140
Over-voltage
Category
IEC61010-1 CAT III 1000 V,
CAT IV 600 V
Environmental Specifications
Operating
Temperature
32 °F to + 122 °F
(0 °C to +50 °C)
Storage
Temperature
-4 °F to 140 °F
(-20 °C to +60 °C)
Operating
Humidity
0 to 95 % (non-condensing)
Operating
Altitude
2000 m
Storage
Altitude
10,000 m
IP Rating
42 (indoor use only)
Drop Test
Requirements
1 m
EMI, RFI, EMC
FCC part 15, IEC/EN 61326-1:1997
class B, IEC/EN 61326:1997 3V/m,
performance criteria B, EN61325
Temperature
Coefficients
Current: 0.1 % of reading per °C
outside 22-24 °C
Voltage: 0.1 % of reading per °C
outside 22-24 °C

Other manuals for Fluke 353

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 353 and is the answer not in the manual?

Fluke 353 Specifications

General IconGeneral
DC voltage1000 V
Low pass filterYes
DC current (max)2000 A
Measuring categoryCAT III 1000V, CAT IV 600V
AC current maximum resolution (probe)1 A
Battery typeAA
Number of batteries supported6
CertificationIEC 61010-2-032, CE, RoHS, EMI, RFI, EMC, IP42
Product colorBlack, Red, Yellow
Operating altitude0 - 2000 m
Non-operating altitude0 - 10000 m
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Weight and Dimensions IconWeight and Dimensions
Depth52 mm
Width98 mm
Height300 mm
Weight814 g