Figure Title Page
1. The Meter ............................................................................................................... 5
2. Position Sensitivity ................................................................................................. 6
3. Performance Test Connections for AC Amps and DC Amps ................................ 8
4. Performance Test Connections for AC Amps, DC Amps, and Frequency ............ 9
5. Performance Test Connections for AC Voltage, DC Voltage, and Frequency ...... 10
6. Performance Test Connections for the iFlex .......................................................... 13
7. Current Test Simulated with Voltage ..................................................................... 14
8. Changing the Batteries ........................................................................................... 20

Other manuals for Fluke 381

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 381 and is the answer not in the manual?

Fluke 381 Specifications

General IconGeneral
Continuity60 Ω
Resistance (max)600 Ω
Resistance (min)6 Ω
Measuring categoryCAT III 1000V, CAT IV 600V
AC voltage resolution (min)600 V
AC current maximum resolution (probe)2500 A
Product colorYellow
Operating altitude0 - 2000 m
Non-operating altitude0 - 12000 m
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)0 - 90 %
Probe length1800 mm
Carrying caseYes
Probe diameter7.5 mm
Weight and Dimensions IconWeight and Dimensions
Depth277 mm
Width88 mm
Height43 mm
Weight350 g