Introduction and Specifications
AC Current Specifications
1
1-23
1-16. AC Current Specifications
Table 1-16. 5720A Series II AC Current Specifications: 99 % Confidence Level
5720A
99%
99 % Confidence Level
Range Resolution Frequency
Absolute Uncertainty
±5 °C from calibration temperature
For fields strengths >0.4 V/m but 3 V/m,
add 1 % of range.
Relative Uncertainty
±1 °C
24 Hours 90 Days 180 Days 1 Year 24 Hours 90 Days
Hz ± (ppm output + nA) ± (ppm output + nA)
220 µA1 nA
010 - 20
020 - 40
040 - 1 k
01k - 5 k
05k - 10 k
0260 + 20
0170 + 12
0120 + 10
0300 + 15
1000 + 80
0280 + 20
0180 + 12
0130 + 10
0320 + 15
1100 + 80
0290 + 20
0190 + 12
0135 + 10
0340 + 15
1200 + 80
0300 + 20
0200 + 12
0140 + 10
0350 + 15
1300 + 80
0260 + 20
0130 + 12
0100 + 10
0250 + 15
0900 + 80
0280 + 20
0150 + 12
0110 + 10
0280 + 15
01000 + 80
2.2 mA 10 nA
010 - 20
020 - 40
040 - 1 k
01k - 5 k
05k - 10 k
0260 + 50
0170 + 40
0120 + 40
0210 + 130
1000 + 800
0280 + 50
0180 + 40
0130 + 40
0220 + 130
1100 + 800
0290 + 50
0190 + 40
0135 + 40
0230 + 130
1200 + 800
0300 + 50
0200 + 40
0140 + 40
0240 + 130
1300 + 800
0260 + 50
0130 + 40
0100 + 40
0250 + 130
0900 + 800
0280 + 50
0150 + 40
0110 + 40
0280 + 130
1000 + 800
22 mA 100 nA
010 - 20
020 - 40
040 - 1 k
01k - 5 k
05k - 10 k
0260 + 500
0170 + 400
0120 + 400
0210 + 700
1000 + 6000
0280 + 500
0180 + 400
0130 + 400
0220 + 700
1100 + 6000
0290 + 500
0190 + 400
0135 + 400
0230 + 700
1200 + 6000
0300 + 500
0200 + 400
0140 + 400
0240 + 700
1300 + 6000
0260 + 500
0130 + 400
0100 + 400
0250 + 700
0900 + 6000
0280 + 500
0150 + 400
0110 + 400
0280 + 700
1000 + 6000
Hz ± (ppm output + µA) ± (ppm output + µA)
220 mA 1 µA
010 - 20
020 - 40
040 - 1 k
01k - 5 k
05k - 10 k
0260 + 5
0170 + 4
0120 + 3
0210 + 4
1000 + 12
0280 + 5
0180 + 4
0130 + 3
0220 + 4
1100 + 12
0290 + 5
0190 + 4
0135 + 3
0230 + 4
1200 + 12
0300 + 5
0200 + 4
0140 + 3
0240 + 4
1300 + 12
0260 + 5
0130 + 4
0100 + 3
0250 + 4
0900 + 12
0280 + 5
0150 + 4
0110 + 3
0280 + 4
1000 + 12
2.2 A 10 µA
020 - 1 k
01 k - 5 k
05 k - 10 k
0290 + 40
0440 + 100
6000 + 200
0300 + 40
0460 + 100
7000 + 200
0310 + 40
0480 + 100
7500 + 200
0320 + 40
0500 + 100
8000 + 200
0300 + 40
0500 + 100
6000 + 200
0350 + 40
0520 + 100
7000 + 200
5725A Amplifier:
11 A 100 µA
040 - 1 k
01 k - 5 k
05 k - 10 k
0370 + 170
0800 + 380
3000 + 750
0400 + 170
0850 + 380
3300 + 750
0440 + 170
0900 + 380
3500 + 750
0460 + 170
0950 + 380
3600 + 750
0300 + 170
0700 + 380
2800 + 750
0330 + 170
0800 + 380
3200 + 750
Note: Maximum output from the calibrator’s terminals is 2.2 A. Uncertainty specifications for 220 µA and 2.2 mA
ranges are increased by a factor of 1.3 plus 2 µA when supplied through 5725A terminals. Specifications are
otherwise identical for all output locations.