Page #11 background imageLoading...
Page #11 background image
Milliamp Process Clamp Meter
Specifications
7
Mechanical Specifications
Size (H X W X L) ............................ 43.7 mm x 70 mm x 246.2 mm
Weight ............................................. 410 g
Environmental Specifications
Operating Temperature ................... -10 °C to 50 °C
Storage Temperature ...................... -25 °C to 60 °C
Operating Humidity ......................... <90 % RH @ <30 °C
<75 % RH @ 30 °C to 50 °C
Operating Altitude ........................... 0 m to 2000 m
IP Rating ......................................... IP 40
Temperature Coefficients ................ 0.1 (/ °C X Specified accuracy for Temperature <18 °C or >28 °C)
Safety .............................................. IEC 61010-1, Pollution degree 2
IEC 61010-2-032: O, other circuits not directly connected to mains.
Electromagnetic Compatibility (EMC)
International .................................... IEC 61326-1: Portable Electromagnetic Environment
IEC 61326-2-2
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency
energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly
connected to a low voltage power supply network that supplies buildings used for domestic purposes.
There may be potential difficulties in ensuring electromagnetic compatibility in other environments
due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide
adequate protection to radio reception in such environments.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected
to a test object.
The equipment may not meet the immunity requirements of this standard when test leads and/or test
probes are connected.
For current measurement with jaw, add 1 mA to specification for EMC fields from 1 V/m to 3 V/m.
Miscellaneous Specifications
Power Requirements ...................... Four AA batteries, Alkaline, IEC LR6
Automatic Time-out (Power) ........... 15 minutes ±1 minute
Automatic Time-out (Backlight) ....... 2 minutes ±10 seconds
Automatic Time-out
(Measurement Spotlight) ................. 2 minutes ±10 seconds

Other manuals for Fluke 773

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 773 and is the answer not in the manual?

Fluke 773 Specifications

General IconGeneral
Operating altitude0 - 2000 m
Storage temperature (T-T)-25 - 60 °C
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)0 - 90 %
Battery typeAA
Power sourceBattery
Battery voltage1.5 V
Battery technologyAlkaline
Number of batteries supported4
Product typeDigital multimeter
Product colorGrey, Red, Yellow
DC current range0 - 0.024 A
DC voltage range0 - 30 V
Placement supportedHandheld multimeter
Basic accuracy (DC current)0.2% + 2 counts
Weight and Dimensions IconWeight and Dimensions
Depth44 mm
Width70 mm
Height246 mm
Weight410 g