Specifications
35
Specifications
Environmental Specifications
-10ºC to +50ºC
-20ºC to +50ºC
Meter Specifications
InGaAs
850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm
+10 dBm to -52 dBm (850 nm)
+10 dBm to -60 dBm (1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm)
±0.2 dB (850 nm)
1
±0.1 dB (1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm)
2
±0.25 dB
Operating temperature
Storage temperature
Detector type
Calibrated wavelengths
Measurement range
Power measurement linearity
Power measurement uncertainty
3
1. For 850 nm, ±0.2 dB for power from 0 dBm to -45 dBm, ±0.25 dB for power < -45 dBm.
2. ±0.1 dB for power from 0 dBm to -55 dBm. ±0.2 dB for power > 0 dBm and < -55 dBm.
3. 23°C ±2°C, power level -20
dBm, continuous wave, 62.5/125 µm at multimode wavelengths, 9/125 µm at 1310 nm, 1490 nm, 1550 nm,
and 1625 nm; add 0.1 dB for 1625 nm.